Introduction
Design a complete BMS for a 16S LiFePO4 battery pack with cell balancing, SOC estimation, and protection. This comprehensive guide covers everything from design through implementation, testing, and deployment.
Design a complete BMS for a 16S LiFePO4 battery pack with cell balancing, SOC estimation, and protection.
Design a complete BMS for a 16S LiFePO4 battery pack with cell balancing, SOC estimation, and protection. This comprehensive guide covers everything from design through implementation, testing, and deployment.
The BQ76940 measures up to 15 cell voltages simultaneously with 0.25mV accuracy. Connect cells in a series stack with the BQ76940 monitoring each cell tap. Multiple ICs can be daisy-chained via a differential I2C (HDQ) interface for packs exceeding 15 cells. Read cell voltages every 250ms. Detect cell voltage out-of-range: overvoltage (>3.65V for LiFePO4) or undervoltage (<2.5V) triggers protection FET cutoff.
10 components required for this project.
| # | Component | Purpose | Qty |
|---|---|---|---|
| 1 | BQ76940 Battery Monitor IC | Voltage measurement for 15-cell packs | x2 |
| 2 | STM32F103 Microcontroller | BMS master controller | x1 |
| 3 | MOSFET (IRFB4110, 100V/180A) | Charge and discharge FET switches | x4 |
| 4 | LiFePO4 Cells (3.2V, 100Ah) | Battery pack (51.2V nominal, 5.12kWh) | x16 |
| 5 | Current Sensor (LEM LTS 25-NP) | Pack current measurement (±25A) | x1 |
| 6 | NTC Thermistors (10kΩ) | Cell temperature monitoring | x8 |
| 7 | Balancing Resistors (10Ω/2W) | Passive cell balancing | x16 |
| 8 | CAN Transceiver (MCP2551) | Communication with inverter/charger | x1 |
| 9 | Isolated DC-DC Converter (5V/3W) | Isolated power for measurement ICs | x2 |
| 10 | Fuse (125A ANL) | Pack-level overcurrent protection | x1 |
Follow these 7 steps carefully.
The BQ76940 measures up to 15 cell voltages simultaneously with 0.25mV accuracy. Connect cells in a series stack with the BQ76940 monitoring each cell tap. Multiple ICs can be daisy-chained via a differential I2C (HDQ) interface for packs exceeding 15 cells. Read cell voltages every 250ms. Detect cell voltage out-of-range: overvoltage (>3.65V for LiFePO4) or undervoltage (<2.5V) triggers protection FET cutoff.
Integrate current over time to track charge and discharge: SOC = SOC_initial + integral(current × dt) / capacity_Ah. The LEM current sensor measures pack current with ±0.5% accuracy at 25°C. Apply temperature correction factor to capacity (LiFePO4 capacity reduces 15% at 0°C, 30% at -20°C). Reset SOC to 100% when charge current drops below C/20 (5A for 100Ah pack) at full charge voltage.
When any cell exceeds 3.40V during charging, activate its balancing resistor (10Ω × 3.2V = 320mA drain) to dissipate excess charge as heat. Continue charging the pack at reduced current while balancing. All cells reach 3.65V simultaneously when balanced. The BQ76940 has onboard balancing FETs for each cell — simply set the CELL_BAL register bits. Monitor balancing resistor temperature; if > 60°C, pause balancing.
Implement hardware and software protection: overvoltage protection (hardware comparator in BQ76940, trips < 1ms), undervoltage (stops discharge protecting against deep discharge), overcurrent charge (>120A trips charge FET), overcurrent discharge (>200A hardware trip), short circuit (hardware current comparator, < 50µs trip), overtemperature (> 55°C stops charge, > 60°C stops discharge), and undertemperature (< 0°C stops charge — lithium plating risk).
SOH measures battery aging: SOH = current_capacity / rated_capacity × 100%. Measure capacity periodically by fully charging, then fully discharging at C/5 rate while integrating coulombs. LiFePO4 can withstand 2000–4000 full cycles to 80% SOH. Track internal resistance by measuring voltage drop on a known current pulse: R_int = ΔV/ΔI. Rising internal resistance is a key aging indicator even before capacity fade.
Implement CAN 2.0B protocol to share BMS data with connected inverter/charger systems. Transmit CAN frames every 100ms: Frame 0x100: pack voltage, pack current, SOC; Frame 0x101: max cell voltage, min cell voltage, max temperature; Frame 0x102: fault status flags; Frame 0x103: allowed charge current limit, allowed discharge current limit (dynamic limits based on SOC and temperature).
Mount NTC thermistors between cells in at least 4 locations across the pack (corners, center). Calculate average, minimum, and maximum temperatures. Implement heating pad control for low-temperature operation: below 10°C, activate heater pad and limit charge current to 0.1C until cells reach 15°C. Above 40°C, derate charge/discharge current linearly. Above 55°C, stop all charging.
Core code for bms_main.cpp:
#include <Wire.h> #define BQ76940_ADDR 0x08 #define SYS_CTRL1 0x04 #define CELLBAL1 0x01 float cellVoltages[16]; float packCurrent = 0; float soc = 100.0; float totalAh = 0; unsigned long lastTime = 0; void readCellVoltages() { for (int i = 0; i < 16; i++) { Wire.beginTransmission(BQ76940_ADDR); Wire.write(0x0C + i * 2); Wire.endTransmission(false); Wire.requestFrom(BQ76940_ADDR, 2); uint16_t raw = (Wire.read() & 0x3F) << 8 | Wire.read(); cellVoltages[i] = raw * 0.000382; } } float readPackCurrent() { float voltage = analogRead(A0) * (3.3 / 1023.0); return (voltage - 2.5) / 0.04; } void updateSOC() { unsigned long now = millis(); float dt_h = (now - lastTime) / 3600000.0; packCurrent = readPackCurrent(); totalAh += packCurrent * dt_h; soc = constrain(100.0 - (totalAh / 100.0) * 100.0, 0, 100); lastTime = now; } void balanceCells() { float maxV = *max_element(cellVoltages, cellVoltages + 16); for (int i = 0; i < 16; i++) { bool balance = (cellVoltages[i] > 3.40) && (maxV - cellVoltages[i] < 0.005); Wire.beginTransmission(BQ76940_ADDR); Wire.write(CELLBAL1 + i / 5); Wire.write(balance ? (1 << (i % 5)) : 0); Wire.endTransmission(); } } void loop() { readCellVoltages(); updateSOC(); balanceCells(); delay(250); }
Test Battery Management System (BMS) by verifying each subsystem individually before full integration.
Verify power voltages, check ground connections, use serial monitor for debug.
An interactive simulator will be available here — simulate circuits and run code in-browser without hardware.